Multifunction device with KNX power supply, IP gateway, relay outputs, and binary inputs.
It has a 640mA power supply, a KNX-IP interface, a climate controller with up to 4 independent thermostats, a logical module, and a multifunction actuator with 12 inputs and 16 outputs (16A C-Load).
4 different configurable channels - shutter channels (up to 8), individual outputs (up to 16), and 2/4-pipe fan coil controls (up to 2).
Short-circuit and overvoltage protection.
Reset button and overload status LED.
KNXnet/IP tunneling protocol (up to 5 connections).
12 analog/digital inputs for the motion sensor, door contact, conventional switches, etc.
A must-have device for any residential, commercial, or hotel application.
Mounting – 12 DIN units.
Multi-function Actuator
ZIO – MB 24/16/08/04/02
ZIO – MB 24/16/08/04/02
Multifunction Actuator series with max 24 channels and min 2 channels.
16A load capacity (up to 3500W) per channel.
Highly suitable for common loads, fluorescent lighting loads, or shutter motors.
One controller for all – can be used for lights, curtains, fan on/off, AC on/off, boiler on/off, FCU valve and fan speed, etc. simultaneously.
Possibility of connecting different phases in adjacent outputs.
Its high load capacity and multifunction capability make the product more robust, reliable, and easy to use in various segments.
Precise installation information on the product, manual push-button, testing, and the status indication is available for a hassle-free installation.
Mounting – 2 to 12 DIN units.
Universal Dimming
ZDIDB DX4/DX2/DX1
ZDIDB DX4/DX2/DX1
Universal Dimmer for lights available in 04/02/01 channels.
Automation detection for the RLC load type also detects frequency automatically.
Dimming pattern selection for CFL and LED lamps.
Manual push-button on the device for dimming control.
Up to 300W per channel for any load CFL, RLC, or LED lamps.
Precise installation information on product, testing, and status indication is available for a hassle-free installation.
Mounting – 2 to 8 DIN units.
Mood Lighting
ZN1IO – RGB X3/X4/DX4
ZN1IO – RGB X3/X4/DX4
3 channel LED and 4 channel LED dimming solution.
Based on varying the voltage by Pulse Width Modulation (PWM).
Load type – 12/24 VDC LED, regulation – constant voltage, max
current/channel – 2.5A (for DX4, 6A per channel), Auxiliary
power – 12/24 VDC.
Different control ways - on/off,
relative dimming and absolute dimming.
Independent channel control and color
selection objects (only for RGB), status objects,
several custom on/off, timers, scenes/sequences.
Testing and programming LED, terminal for external supply,
terminal for LED control, and KNX connector block available
on the product.
KNX-DALI interface to control up to 64 ballasts,
which can be associated in up to 32 groups of different sizes.
Its 1.54” display shows error indication for each ballast.
External power supply of 110/230V 50/60HZ.
Manual control through buttons and status indication through the display.
A perfect solution for lighting in corporate office reception,
work stations, passages, lobbies to achieve maximum dimming
with minimum wiring.
Can be used for tunable light for 16
groups and 16 independent light controls.
Possibility to integrate with
luminosity sensor and HVAC system over
KNX to implement DayLight Harvesting in an
office to reduce energy consumption significantly.
Mounting – 4.5 DIN units.
DALI Broadcast
ZDI – DLB 4/6
ZDI – DLB 4/6
KNX Interface to control up to 6 channels of up to 20 ballasts with broadcast commands. (for DLB4, up to 4 channels of up to 20 ballasts)
Possibility to control up to 10 scenes/sequences for each channel.
Allows manual control and status indicator LEDs for each channel.
Ballast replacement allowed with automatic detection.
External 110-230VAC 50/60Hz power supply.
Highly suitable for long corridors, passages, pathways, lobbies, etc. It can also be used in Residences.
Mounting – 4.5 DIN units.
AC Gateways
KLIC – DI/MITT V2/LG1/FJ/TS/PA
KLIC – DI/MITT V2/LG1/FJ/TS/PA
KNX to HVAC gateway for seamless integration with AC.
Available for Daikin, Mitsubishi, LG, Toshiba, Panasonic, and Fujitsu as of now.
It’s bidirectional communication with various brands of ACs over KNX.
It allows on/off, setpoint temperature, mode selection, fan speed, swing control.
It also provides advanced functions like set point limits, automatic switch-off, scenes, etc.
Communication with each indoor unit and in case of failure, particular indoor won’t work but will not affect others as it happens with the system which controls outdoor instead of indoor.
It also has 2 analog-binary inputs for the motion sensor, dry contact for switches, temperature probe, etc.
Safe, reliable, and easy installation.
Mounting – inside each indoor unit or DB or junction box.
Analog/Digital Input
ZIO – QUAD/RQUAD8
ZIO – QUAD/RQUAD8
Dry contact analog/digital inputs available in 4 or 8 nos.
Can be used to connect motion sensor, temperature probes, or binary input to conventional switch.
Possible to control lights, curtains, scenes, dimming (need to have a push-button switch), etc. if connected to the conventional switch.
Up to 3 individual detection channels with multiple actions and options, luminosity detection, and occupation detection algorithm.
It is majorly used to control balcony/terrace lights, washroom lights, storeroom lights, servant room lights, etc.
Can fit in a regular metal box (not for RQUAD, DIN unit) to reduce cable lengths.
Mounting – metal box or false ceiling. For RQUAD in the
distribution board.
Power Supply
ZPS - 160/320/640mA
ZPS - 160/320/640mA
KNX power supply available with 160, 320, and 640mA.
It supports max consumption of 640mA, i.e., up to 64 KNX devices. More than 64, required additional power supply with line coupler to connect them to have a single KNX line.
Generate and feed 29 VDC to all products. Vin 230 VAC.
Reset button and overload status LED.
Short-circuit and overload protection.
Mounting – 160mA – 2 DIN units, 320mA, and 640mA – 4.5 DIN units.
Sensors
ZPD – C30L
ZPD – C30L
KNX presence detector with luminosity detection.
360 deg detection with 4 inbuilt sensors in each direction having a 30 m diameter detection area.
Calibration of luminosity sensor for workstations and constant luminosity regulation.
Enabling/disabling detection LED indicators by parameter.
HVAC control with a filter that makes the HVAC machine turn on only when room presence is detected in a continuous way avoiding it from turning on during a short time.
Logical programming with door contact, HVAC function,
lights intensity, shutter control is possible.
EyeZen IN
EyeZen IN
EyeZen IN
Supported by Zennio devices with built-in inputs
Motion detection through PIR technology
Detection diameter of up to 6m
Lighting level sensor with human eye spectral sensitivity
External dimensions: Ø58 x 41mm
Internal dimensions: Ø48.3 x 41mm
Cut dimensions: Ø51mm hole saw blade
False-ceiling flush-mounted
Conformity with the CE directives (CE-mark on its side)